877 |
sba |
Hardware - PC |
2023-09-13 18:00:00 |
2023-09-29 18:30:00 |
PC failed to restart after a UPS restart |
System restarted |
766 |
sba |
Hardware - Instrument |
2021-01-27 00:00:00 |
2021-08-31 00:06:00 |
Tipping bucket grossly under-reporting precipitation amounts; begin time of malfunction unknown |
Tipping bucket leveled, cleaned and tipped twice (0.508 mm reported) at 00:06 UTC on 2021-08-31 |
649 |
sba |
Hardware - Air Conditioner |
2019-10-01 18:00:00 |
2019-10-11 18:00:00 |
Air conditioner failure; radar will be intermittently operational; replacement likely to occur in 1-2 weeks; |
On-site repair. |
634 |
sba |
Communication - Cellular |
2019-03-06 03:00:00 |
2019-03-06 23:00:00 |
Can't reach cellular router. Power outages in the area. Generator requires maintenance and is currently disabled. |
Power restored. |
573 |
sba |
Power Failure |
2018-01-10 23:00:00 |
2018-01-23 17:00:00 |
Equipment powered down due to malfunctioning air conditioner and overheating. |
AC repaired. |